I. Et qualis est vestibulum materials de Refrigeration machinam oportet obviam generali signa mechanica vestibulum. Mechanica materiae, qui veniunt in contactum cum lubricating oleum debet esse chemica firmum ad lubricating oleum et poterit resistere mutationes in temperatus et pressura per operationem.
II. Fontem salus valvae sit installed inter suctu latus et exhauriunt parte compressor. It is usually stipulated that the machine should be automatically turned on when the pressure difference between the inlet and exhaust is greater than 1.4MPa (the low pressure of the compressor and the pressure difference between the inlet and exhaust of the compressor is 0.6MPa), so that the air returns to the low-pressure cavity, and no stop valve should be installed between its channels.
III. Salus aeris influunt cum sciger vere est provisum est in compressor cylindri. Cum pressura in cylindrici est maius quam exhaurit a 0,2 ~ 0.35MPa (METIOR pressura), salus operimentum automatice opens.
IV. Condensers, liquore repono cogitationes (including altum et humilis pressura liquore repono cogitationes, exhauriunt cados), Intercoolers et alia apparatu debet instructi vere salute valvulae. Eius foramen pressura plerumque 1.85MPA ad altus-pressura apparatu et 1.25MPA pro humilis-pressura apparatu. A prohibere valvae sit installed in fronte salus valvae cuiusque apparatu, et in aperto statu signatum plumbum.
V. Stainers installers outdoors operuit cum peropere ad vitare solis.
VI. Pressura gauges et thermometris debet installed in utraque suctu et exhauriunt latera compressor. Pressio MODULUS sit installed inter cylindri et clausa off valvae et imperium valvae sit installed; Thermometrum dura mounted manica quae intra 400mm ante vel post clausa off valvae fretus influunt directionem et sleeve esse intra tibia.
7. Two inlets and outlets should be left in the machine room and equipment room, and a spare main switch (accident switch) for the compressor power supply should be installed near the outlet, and it is only allowed to be used when an accident occurs and the emergency stop occurs.VIII. VENTILATIO cogitationes sit installed in apparatus locus et apparatu locus, et munus requirit ut amet aer mutari VII temporibus per hora. Initium switch fabrica debet installed utrumque domesticas et foris.IX. Ut ne accidentia (ut ignis, etc.) ex fieri sine accidentibus ad continens, subitis fabrica debet installed in refrigerationem ratio. In discrimine, in Gas in continens potest dimisit per cloacam.