Refrigerant, etiam quae refrigerare, est opus substantiam in refrigeratur ratio. In praesens, sunt plus quam LXXX species substantiae, quae possunt esse sicut Refrigerant. Maxime commune refrigerantes sunt freon (including: R22, R134a, R407C, R410A, R32, etc), Ammonia (NH3), aqua (H2o), R600A).
Et Impact Indicatores de Refrigerants in global environment maxime includit: Ozone deperditionem potentiale (ODP) et global calefactio potential (GWP); Praeter impulsum elit refrigerants etiam gratum salus praesidio populi vitae et possessionem.
ODP Ozone deperditionem potentiale: indicat facultatem chlorofluorocarbons in atmosphaera perdere ozone iacuit. Et minor est valorem, in melius environmental characteres de refrigerantis. Refrigerant cum ODP values minus quam vel aequalis ad 0.05 sunt considerari gratum secundum current levels.
GWP global calefactionementi potential: an indicator de caeli impulsum per CONSERVATORIUM Gas emissiones, significans quod in quadam tempus (XX annis, C annos, D annis), in qualis CO2 1.0. Usually calculate GWP secundum C annos, significatum est GWP100, "Montrealensi protocol" et "Kyoto protocollo" et usus GWP100.
I. Ordo Refrigerants
Secundum ad GB / T 7778-2017, refrigerant salus est dividitur in VIII genera, nimirum: A1, A2L, A2, A3, B1, B2L, B3 est maxime periculosum.
Solum campester of Common Refrigerants sunt;
Type A1: R11, R12, R13, R113, R114, R115, R116, R22, R124, R23, R125, R134a,, R236fa, R218, RC318, R401a, R401b, R402a, R402b, R403a, R403b, R404a, R407a, R407b, R407c, R407d, R408a, R409a, R410a, R417a, R422d, R500, R501, R502, R507a, R508a, R508b, R509a, R513a, R744
Type A2: R142B, R152A, R406A, R411A, R411B, R412A, R413a, R415B, R418a, R419a, R512A
A2L Categoria: R143A, R32, R1234YF, R1234ZE (E)
Classis A3: R290, R600, R600A, R601a, R1270, Re170, R510A, R511A
Genus B1: R123, R245FA
B2L Categoria: R717
According to the evaporation temperature ts of the refrigerant under standard atmospheric pressure (100kPa), it can be divided into: high-temperature refrigerant, medium-temperature refrigerant, and low-temperature refrigerant.
Humilis-pressura summus temperatus refrigeratur: et evaporatio temperatus est altior quam 0 ° C et condensationem pressura est inferior quam 29.41995 × 104Pa. Hae refrigors sunt idoneam usum in centrifuga refrigeration compressors in aerem condiciones systems.
Medium-pressura medium-temperatus refrigeratur: medium-pressura medium-temperatus refrigeratur: evaporatio temperatus -50 ~ 0 ° C, condensing pressura (196,113 ~ 29.41995) × 104Pa. Hoc genus refrigerare est plerumque in Ordinarius unum scaena compressionem et duos scaena compressionem Piston refrigeration systems.
High-pressura et humilis-temperatus refrigerare: summus pressura et humilis-temperatus refrigeratur: et evaporatio temperatus est inferior quam -50 ° C, et condensationem pressura est altior quam 196.133 × 104Pa pressura est altior quam 196.133 × 104Pa. Hoc genus refrigerare est idoneam ad humilis-temperatus parte cascade refrigerationem fabrica vel humilis-temperatus fabrica infra -70 ° c.
Post tempus: Dec-28-2022